TESTUPS
Explainer

EMC testing: what it is and how it is done.

Electromagnetic compatibility testing checks two things: that a product does not disturb other equipment, and that it keeps working when other equipment disturbs it.

Emission tests

  • Radiated emissions: an antenna in a chamber measures what the product radiates, usually from 30 MHz upward
  • Conducted emissions: a LISN measures the noise the product pushes back into its mains cable, typically 150 kHz to 30 MHz
  • Harmonics and flicker: what the product does to the mains voltage

Immunity tests

  • Radiated immunity: the product is exposed to a known field (IEC 61000-4-3)
  • Conducted immunity: disturbances injected into cables (IEC 61000-4-6)
  • Transients: ESD, burst, surge, dips and interruptions (IEC 61000-4-2, -4-4, -4-5, -4-11)

Where the tests happen

Formal tests take place in a full-compliance laboratory: an anechoic chamber for radiated tests, shielded rooms for conducted tests, and calibrated test systems. Many manufacturers also run a pre-compliance bench so that the formal test is not the first time a product meets an antenna.

← All articles

Planning an EMC lab or an upgrade?

TESTUPS designs, sources and supplies EMC chambers, test systems and components, and supports installation, site validation and accreditation preparation.